484 research outputs found

    Low frequency noise due to magnetic inhomogeneities in submicron FeCoB/MgO/FeCoB magnetic tunnel junctions

    Full text link
    We report on room temperature low frequency noise due to magnetic inhomogeneities/domain walls (MI/DWs) in elliptic submicron FeCoB/MgO/FeCoB magnetic tunnel junctions with an area between 0.0245 and 0.0675{\mu}m2. In the smaller area junctions we found an unexpected random telegraph noise (RTN1), deeply in the parallel state, possibly due to stray field induced MI/DWs in the hard layer. The second noise source (RTN2) is observed in the antiparallel state for the largest junctions. Strong asymmetry of RTN2 and of related resistance steps with current indicate spin torque acting on the MI/DWs in the soft layer at current densities below 5x10^5 A/cm2.Comment: 12 pages, 4 figure

    Determination of partial photoionisation cross sections of methyl bromide in the first autoionisation range by use of spin polarisation photoelectron spectroscopy

    Get PDF
    SchÀfers F, Baig MA, Heinzmann U. Determination of partial photoionisation cross sections of methyl bromide in the first autoionisation range by use of spin polarisation photoelectron spectroscopy. Journal of Physics B: Atomic, Molecular and Optical Physics. 1983;16(1):L1-L6.Using recent experimental data on photoelectron spin polarisation combined with the high-resolution spectrum of methyl bromide, which has also been recently reported, the partial photoionisation cross sections for the ionisation of CH3Br from the 4 pi ground-state orbital into the energy degenerate continua epsilon sigma , epsilon pi and epsilon delta have been determined separately. Quantitative results, obtained for the autoionising resonances between 116 and 118 nm, are reported and discussed

    Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional

    Get PDF
    Respiratory motion is known to degrade image quality in PET imaging. The necessary acquisition time of several minutes per bed position will inevitably lead to a blurring effect due to organ motion. A lot of research has been done with regards to motion correction of PET data. As full-body PET-MRI became available recently, the anatomical data provided by MRI is a promising source of motion information. Current PET-MRI-based motion correction approaches, however, do not take into account the available information provided by PET data. PET data, though, may add valuable additional information to increase motion estimation robustness and precision.In this work we propose a registration functional that is capable of performing motion detection in gated data of two modalities simultaneously. Evaluation is performed using phantom data. We demonstrate that performing a joint registration of both modalities does improve registration accuracy and PET image quality.<br

    The Energy Materials in-Situ Laboratory Berlin (EMIL) at BESSY II

    Get PDF
    The Helmholtz Center Berlin (HZB) and the Max-Planck Society (MPG) strengthen their research in renewable energies with the implementation of the joint Energy Material in-Situ Lab Berlin (EMIL) at the third generation light source BESSY II. The new facility is dedicated to the in-situ and in-system x-ray analysis of materials and devices for photovoltaic applications, (photo-) catalytic processes, energie conversion and storage. To obtain a comprehensive understanding of the involved materials, spectroscopic methods with x-rays from the soft- up to the hard x-ray regime reveal an almost complete picture of their chemical and electronic properties. The contribution presents the layout of the x-ray beamlines and their performance in terms of photon flux, energy resolution and spot sizes

    Which Aortic Valve Can Be Surgically Reconstructed?

    Get PDF
    Purpose of Review Preservation or repair of the aortic valve has evolved dynamically in the past 20 years. It leads to a high freedom from valve-related complications if an adequate valve durability can be achieved; it may possibly also improve survival. To date, little structured information is available about which valves can be repaired and which should better be replaced. Recent Findings For surgical decision-making, the size of the aortic root is important and the anatomy of the aortic valve must be considered. In the presence of root aneurysm, most tricuspid and bicuspid aortic valves can be preserved. In aortic regurgitation and normal aortic dimensions, the majority of tricuspid and bicuspid aortic valves can be repaired with good long-term durability. In bicuspid aortic valves, the morphologic characteristics must be taken into consideration. Unicuspid and quadricuspid aortic valves can be repaired in selected cases. Generally, cusp calcification is a sign of a poor substrate for repair; the same is true for cusp retraction and cusp destruction due to active endocarditis. They are associated with limited valve durability. Summary Using current concepts, many non-calcified aortic valves can be repaired. Modern imaging, in particular three-dimensional transesophageal echocardiography (TEE), should be able to define repairable aortic valves with a high probability

    Systematic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT

    Full text link
    Background: The “back-translation” of clinically available protocols to measure myocardial perfusion to preclinical imaging in mouse models of human disease is attractive for basic biomedical research. With respect to singlephoton emission computed tomography (SPECT) approaches, clinical myocardial perfusion imaging protocols are established with different 99mTc-labeled perfusion tracers; however, studies evaluating and optimizing protocols for these tracers in high-resolution pinhole SPECT in mice are lacking. This study aims at evaluating two clinically available 99mTc-labeled myocardial perfusion tracers (99mTc-sestamibi vs. 99mTc-Tetrofosmin) in mice using four different imaging protocols. Methods: Adult C57BL/6 male mice were injected with 99mTc-sestamibi (MIBI) or 99mTc-Tetrofosmin (TETRO) (4 MBq/g body weight) either intravenously through the tail vein (n = 5) or retroorbitally (n = 5) or intraperitoneally (i. p.) under anesthesia (n = 3) or i.p. in an awake state (n = 3) at rest. Immediately after injection, a multi-frame singlephoton emission computed tomography/computed tomography (SPECT/CT) acquisition was initiated with six subsequent time frames of 10 min each. Reconstructed images of the different protocols were assessed and compared by visual analysis by experts and by time-activity-curves generated from regions-of-interest for various organs (normalized uptake values). Results: Visually assessing overall image quality, the best image quality was found for MIBI for both intravenous injection protocols, whereas TETRO only had comparable image quality after retroorbital injections. These results were confirmed by quantitative analysis where left ventricular (LV) uptake of MIBI after tail vein injections was found significantly higher for all time points accompanied with a significantly slower washout of 16% for MIBI vs. 33% for TETRO (p = 0.009) from 10 to 60 min post injection (PI). Interestingly, LV washout from 10 to 60 min PI was significantly higher for TETRO when applied by tail vein injections when compared to retroorbital injections (22%, p = 0.008). However, liver uptake was significant and comparable for both tracers at all time points. Radioactivity concentration in the lungs was negligible for all time points and both tracers. Conclusion: Intravenous MIBI injection (both tail vein and retroorbital) results in the best image quality for assessing myocardial perfusion of the murine heart by SPECT/CT. TETRO has a comparable image quality only for the retroorbital injection route

    Modulation of Voltage-Gated Sodium Channels by Activation of Tumor Necrosis Factor Receptor-1 and Receptor-2 in Small DRG Neurons of Rats

    Get PDF
    Tumor necrosis factor-(TNF-) is a proinflammatory cytokine involved in the development and maintenance of inflammatory and neuropathic pain. Its effects are mediated by two receptors, TNF receptor-1 (TNFR-1) and TNF receptor-2 (TNFR-2). These receptors play a crucial role in the sensitization of voltage-gated sodium channels (VGSCs), a key mechanism in the pathogenesis of chronic pain. Using the whole-cell patch-clamp technique, we examined the influence of TNFR-1 and TNFR-2 on VGSCs and TTXresistant NaV1.8 channels in isolated rat dorsal root ganglion neurons by using selective TNFR agonists. The TNFR-1 agonist R32W (10 pg/mL) caused an increase in the VGSC current (I Na(V) ) by 27.2 ± 5.1%, while the TNFR-2 agonist D145 (10 pg/mL) increased the current by 44.9 ± 2.6%. This effect was dose dependent. Treating isolated NaV1.8 with R32W (100 pg/mL) resulted in an increase in I NaV(1.8) by 18.9 ± 1.6%, while treatment with D145 (100 pg/mL) increased the current by 14.5 ± 3.7%. Based on the current-voltage relationship, 10 pg of R32W or D145 led to an increase in I Na(V) in a bell-shaped, voltage-dependent manner with a maximum effect at −30 mV. The effects of TNFR activation on VGSCs promote excitation in primary afferent neurons and this might explain the sensitization mechanisms associated with neuropathic and inflammatory pain

    SPECT- and PET-Based Approaches for Noninvasive Diagnosis of Acute Renal Allograft Rejection

    Full text link
    Molecular imaging techniques such as single photon emission computed tomography (SPECT) or positron emission tomography are promising tools for noninvasive diagnosis of acute allograft rejection (AR). Given the importance of renal transplantation and the limitation of available donors, detailed analysis of factors that affect transplant survival is important. Episodes of acute allograft rejection are a negative prognostic factor for long-term graft survival. Invasive core needle biopsies are still the “goldstandard” in rejection diagnostics. Nevertheless, they are cumbersome to the patient and carry the risk of significant graft injury. Notably, they cannot be performed on patients taking anticoagulant drugs. Therefore, a noninvasive tool assessing the whole organ for specific and fast detection of acute allograft rejection is desirable. We herein review SPECT- and PET-based approaches for noninvasive molecular imaging-based diagnostics of acute transplant rejection

    Direct imaging of the structural change generated by dielectric breakdown in MgO based magnetic tunnel junctions

    Full text link
    MgO based magnetic tunnel junctions are prepared to investigate the dielectric breakdown of the tunnel barrier. The breakdown is directly visualized by transmission electron microscopy measurements. The broken tunnel junctions are prepared for the microscopy measurements by focussed ion beam out of the junctions characterized by transport investigations. Consequently, a direct comparison of transport behavior and structure of the intact and broken junctions is obtained. Compared to earlier findings in Alumina based junctions, the MgO barrier shows much more microscopic pinholes after breakdown. This can be explained within a simple model assuming a relationship between the current density at the breakdown and the rate of pinhole formation
    • 

    corecore